Print

Advanced Steel Construction

Vol. 14, No. 3, pp. 392-411(2018)


FINITE ELEMENT ANALYSIS OF

DEMOUNTABLE STEEL-CONCRETE COMPOSITE BEAMS

UNDER STATIC LOADING

 

V.I. Patel1,2* , B. Uy2,3, S.W. Pathirana2, S. Wood2, M. Singh2 and B. T. Trang2

1 School of Engineering and Mathematical Sciences, La Trobe University, Bendigo, VIC 3552, Australia

2 Centre for Infrastructure Engineering and Safety, School of Civil and Environmental Engineering, The University of New South Wales, NSW 2232, Australia

3 School of Civil Engineering, The University of Sydney, Sydney, NSW 2006, Australia

*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)

Received: 29 August 2016; Revised: 23 June 2017; Accepted: 20 August 2017

 

DOI:10.18057/IJASC.2018.14.3.5

 

View Article   Export Citation: Plain Text | RIS | Endnote

ABSTRACT

This paper investigates the innovative beam-slab connectors to enable steel-concrete framed structures to be made demountable. A computational simulation for determining the fundamental performance of the demountable composite beams with hollow core concrete slabs, profiled steel deck and bolted shear connectors is developed using the computational code ABAQUS. This numerical model was employed to compare the strength, stiffness and ductility of conventional composite beams utilising welded shear connectors with that of demountable steel-concrete beams utilising blind bolts. The bolted shear connectors not only overcome problems that prevent rehabilitation of existing composite beams with headed studs but also allow for the demountability in the composite beams. The adequacy of the developed computational models is evaluated by verifying the computational results against the corresponding experimental performance. The verification demonstrates that the computational simulations agree with the test performance. The numerical prediction indicated that the shear capacity of blind bolts used in demountable composite metal decking slabs is higher than that of welded connectors utilised in the conventional steel-concrete composite beams. It is found that the composite beams with bolted connectors can be made demountable up to a load of about 50% of the ultimate load which is greater than typical service loads. The strength of shear connectors obtained from the finite element models and experiments were compared with the predicted strength using Eurocode 4 and AS2327.1-2003. It appears that Eurocode 4 and AS2327.1-2003 provide the conservative solutions for the design of shear connector strengths.

 

KEYWORDS

Demountable composite beams, bolted connectors, finite element analysis, profile slabs, solid slabs, blind bolts


REFERENCES

[1] Lam, D., Elliott, K.S. and Nethercot, D.A., “Push-off Tests on Shear Studs with Hollow-cored Floor Slabs”, The Structural Engineer, 1998, Vol. 76, No. 9, pp.167-174.

[2] Lam, D., Elliott, K.S. and Nethercot, D.A., “Parametric Study on Composite Steel Beams with Precast Concrete Hollow Core Floor Slabs”, Journal of Constructional Steel Research, 2000, Vol. 54, No. 2, pp. 283-304.

[3] Ellobody, E. and Young, B., “Performance of Shear Connection in Composite Beams with Profiled Steel Sheeting”, Journal of Constructional Steel Research, 2006, Vol. 62, No. 7, pp. 682-694.

[4] Eurocode 4. Design of Composite Steel and Concrete Structures–Part 1.1, General Rules and Rules for Buildings, London, UK: British Standards Institution; 2004. BS EN 1994-1-1.

[5] Pavlović, M., Marković, Z., Veljković, M. and Buđevac, D., Bolted Shear Connectors vs. Headed Studs Behaviour in Push-out Tests, Journal of Constructional Steel Research, 2013, Vol. 88, pp. 134-149.

[6] Dai, X.H., Lam, D. and Saveri, E., “Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors”, Journal of Structural Engineering, ASCE, 2015, Vol. 141, No. 11, 04015025.

[7] Rahman, N., Lam, D., Dai, X. and Ashour, A.F., “Experimental Study on Demountable Shear Connectors in Composite Slabs with Profile Decking”, Journal of Constructional Steel Research, 2016, Vol. 122, pp. 178-189.

[8] Moynihan, M.C. and Allwood, J.M., “Viability and Performance of Demountable Composite Connectors”, Journal of Constructional Steel Research, 2014, Vol. 99, pp. 47-56.

[9] Mirza, O. and Uy, B., “Effects of Strain Regimes on the Behaviour of Headed Stud Shear Connectors for Composite Steel-concrete Beams”, Advanced Steel Construction, 2010, Vol. 6, No. 1, pp. 635-661.

[10] Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X., “Flexural Behaviour of Composite Steel-concrete Beams Utilising Blind Bolt Shear Connectors”, Engineering Structures, 2016, Vol. 114, pp. 181-194.

[11] Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X., “Bolted and Welded Connectors for the Rehabilitation of Composite Beams”, Journal of Constructional Steel Research, 2016, Vol. 125, pp. 61-73.

[12] Loh, H.Y., Uy, B. and Bradford, M.A., “The Effects of Partial Shear Connection in Composite Flush End Plate Joints Part I – Experimental Study”, Journal of Constructional Steel Research, 2006, Vol. 62, No. 4, pp. 378-390.

[13] Wang, J.F., Han, L.H. and Uy, B., “Behaviour of Flush End Plate Joints to Concrete-filled Steel Tubular Columns”, Journal of Constructional Steel Research, 2009, Vol. 65, No, 4, pp. 925-939.

[14] Mirza, O. and Uy, B., “Behaviour of Composite Beam-column Flush End-plate Connections subjected to Low-probability, High-consequence Loading”, Engineering Structures, 2011, Vol. 33, No. 2, pp. 647-662.

[15] Liu, X., Bradford, M.A. and Lee, M.S.S., “Behavior of High-strength Friction-grip Bolted Shear Connectors in Sustainable Composite Beams”, Journal of Structural Engineering, 2015, Vol. 114, No. 6, 04014149.

[16] Ataei, A., Bradford, M.A., Liu, X., “Experimental Study of Flush End Plate Beam-to-column Composite Joints with Precast Slabs and Deconstructable Bolted Shear Connectors”, Structures, 2016, Vol. 7, pp. 43-58.

[17] Ban, H., Uy, B., Pathirana, S. W., Henderson, I., Mirza, O. and Zhu, X., “Time-dependent Behaviour of Composite Beams with Blind Bolts under Sustained Loads”, Journal of Constructional Steel Research, 2015, Vol. 112, pp. 196-207.

[18] Uy, B., Patel, V., Li, D. and Aslani, F., “Behaviour and Design of Connections for Demountable Steel and Composite Structures”, Structures, 2017, Vol. 9, pp. 1-12.

[19] Vasdravellis, G., Uy, B., Tan, E.L., Kirkland, B., “The Effects of Axial Tension on the Hogging-moment Regions of Composite Beams”, Journal of Constructional Steel Research, 2012, Vol. 68, pp. 20-33.

[20] Vasdravellis, G., Uy, B., Tan, E.L., Kirkland, B., “The Effects of Axial Tension on the Sagging-moment Regions of Composite Beams”, Journal of Constructional Steel Research, 2012, Vol. 72, pp. 240-253.

[21] Vasdravellis, G., Uy, B., Tan, E.L., Kirkland, B., “Behaviour and Design of Composite Beams Subjected to Negative Bending and Compression”, Journal of Constructional Steel Research, 2012, Vol. 79, pp. 34-47.

[22] Vasdravellis, G., Uy, B., Tan, E.L., Kirkland, B., “Behaviour and Design of Composite Beams subjected to Sagging Bending and Axial Compression”, Journal of Constructional Steel Research, 2015, Vol. 110, pp. 29-39.

[23] ABAQUS User’s Manual, Version 6.12-1, Hibbit, Karlsson and Sorensen, Inc., Pawtucket, R.I., 2012.

[24] Uy, B. and Bradford, M., “Composite action of Structural Steel Beams and Precast Concrete Slabs for the Flexural Strength Limit State”, Australian Journal of Structural Engineering, 2006, Vol. 7, No. 2, pp. 1-10.

[25] Mirza, O., Uy, B. and Ha, L., “Time-dependent Analysis of Composite Steel-concrete Beams with Innovative Deep Trapezoidal Decks”, Steel and Composite Structures-Proceedings of the 4th International Conference, 2010.

[26] Standard Australia, Australian Standard AS 3600-2009 Concrete Structures, 2009, Australia

[27] Standard Australia, Australian Standard, Steel Structures, AS4100-1998 (incorporating Amendment 1-2012), 1998, Australia.

[28] Standard Australia, AS/NZS 2327 Composite Structures Part 1: Simply supported Beams, Sydney, 2003.

[29] AS 3600-2009. Concrete Structures, Sydney, New South Wales, Australia: Standard Australia; 2009.

[30] Carreira, D. J. and Chu, K. H., “Stress-strain Relationship for Plain Concrete in Compression”, ACI Journal, 1985, Vol. 82, No. 6, pp. 797-804.

[31] Bažant, Z. P. and Becq-Giraudon, E., “Statistical Prediction of Fracture Parameters of Concrete and Implications for Choice of Testing Standard”, Cement and Concrete Research, 2002, Vol. 32, No. 4, pp. 529-556.

[32] Mirza, O. and Uy, B., “Numerical Modelling of Short and Long Term Behaviour of Headed Stud Shear Connector in Composite Steel-concrete Beams”, Incorporating Sustainable Practice in Mechanics of Structures and Materials, CRC press, 2010, pp. 91-96.

[33] Kwon, G., Engelhardt, M.D. and Klingner, R.E., “Behavior of Post-installed Shear Connectors under Static and Fatigue Loading”, Journal of Constructional Steel Research, 2010, Vol. 66, No. 4, pp. 532-541.

[34] Lam, D. and Uy, B., “Recent Research and Development in Composite Steel Beams with Precast Hollow Core Slabs”, Steel Construction-Journal of the Australian Institute of Steel Construction, 2003, Vol. 37, No. 2, pp. 1-13.