Vol. 6, No. 2, pp. 803-816 (2010)
EVALUATION OF THE REMAINING SHEAR CAPACITY IN CORRODED STEEL I-BEAMS
Y. Sharifi 1,* and R. Rahgozar 1
1 Civil Engineering Department, Kerman University, Kerman, Iran
*(Corresponding author: E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 13 July 2009; Revised: 24 September 2009; Accepted: 30 November 2009
View Article |
Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
There are a large number of steel structures subjected to corrosion due to environmental exposure; which results in reduction of its load carrying capacity. In this paper, thickness loss data were compiled from three samples of corrosion damaged I-beams, removed from a petrochemical industry. Common examples of corrosion that were found included damage loss of section in flanges and holes in the web which is likely to reduce the shear capacity significantly. The collected data was used to calculate the percentage of remaining shear capacity. Corrosion damaged model was developed for steel I-beams based on average measured thicknesses of corroded beams. Formulas were developed to relate the percentage of remaining shear capacity to percentage thickness loss of the corrosion damaged I-beam. It will be shown that very few approximations were needed to derive these analytical relations. The effects of corrosion on steel beams are analyzed by evaluating the remaining capacity with regard to shear failure. Hence, the results of this study can be used for better prediction of the service life for deteriorating steel beams.
KEYWORDS
Corrosion; steel beams; damaged model; remaining shear capacity
REFERENCES
[1] Paik, J.K., Lee, J.M. and Ko, M.J., “Ultimate Compressive Strength of Plate Elements with Pit Corrosion Wastage”, Journal of Engineering Maritime Environmental, 2003, Vol. 217, No. M4, pp. 185–200.
[2] Paik, J.K., Lee, J.M. and Ko, M.J., “Ultimate Shear Strength of Plate Elements with Pit Corrosion Wastage”, Thin-Walled Structures, 2004, Vol. 42, pp. 1161–76.
[3] Nakai, T., Matsushita, H. and Yamamoto, N., “Effect of Pitting Corrosion on Strength of Web Plates Subjected to Patch Loading”, Thin-Walled Structures, 2006, 44, pp. 10-19.
[4] Kulicki, J.M., Prucs, Z., Sorgenfrei, D.F. and Mertz, D.R., “Guidelines for Evaluating Corrosion Effects in Existing Steel Bridges”, National Cooperative Highway Research Program, Report 333, Transportation Research Board, National Research Council, Washington, D.C; 1990.
[5] Czarnecki, A.A. and Nowak, A.S., “Time-Variant Reliability Profiles for Steel Girder Bridges”, Structural Safety, Elsevier, 2008, Vol. 30, pp. 49-64.
[6] Kayser, J.R. and Nowak, A.S., “Capacity Loss Due to Corrosion in Steel-Girder Bridges”, Journal of Structural Engineering, ASCE, 1989, Vol. 115, pp. 1525-1537.
[7] Kayser, J.R., “The Effects of Corrosion on the Reliability of Steel Girder Bridges”, PhD thesis, Department of Civil Engineering, University of Michigan, USA, 1988.
[8] Albrecht, P. and Naeemi, A.H., “Performance of Weathering Steel in Bridges”, National Cooperative Highway Research Program, Report 272, Transportation Research Board, National Research Council, Washington, D. C., 1984.
[9] Rahgozar, R., “Remaining Capacity Assessment of Corrosion Damaged Beams using Minimum Curves”, Journal of Constructional Steel Research, Elsevier, 2009, Vol. 65, pp. 299-307.
[10] Rahgozar, R., “Fatigue Endurance of Steel Structures Subjected to Corrosion”, PhD. Thesis, Department of Civil Engineering, University of Bristol, UK, 1998.
[11] Sharifi, Y. and Rahgozar, R., “Simple Model to Estimate the Remaining Moment Capacity of Corroded Varying Thickness Loss of I-Beam Sections”, Proceeding of the 11th National Corrosion Congress, Kerman, Iran, 2009, pp. 1237-1244.
[12] Nethercot, D.A., “Limit States Design of Structural Steelwork”, Third Edition, Spon Press, London, UK, 2001.
[13] Fontana, M.G., “Corrosion Engineering”, McGraw Hill Book Company, New York, Third Edition, 1987.
[14] Kayser, J.R. and Nowak, A.S., “Evaluation of Corroded Steel Bridges”, Proceedings of Structures Congress Related to Bridge and Transmission Line Structures, American Society of Civil Engineers, Orlando, Florida; 1987, pp. 35-47.
[15] Trahair, N.S., Bradford, M.A. and Nethercot D.A, “The Behavior and Design of Steel Structures to BS5950”, Third Edition, British, London, Spon Press, Taylor & Francis Group, 2001.
[16] Timoshenko, S.P. and Gere, J.M., “Theory of Elastic Stability”, McGraw-Hill Book Company, 1961.
[17] Stowell, E.Z., Heimerl, G.J., Libove, C. and Lundquist E.E., “Buckling Stresses for Flat Plates and Sections”, Transaction of ASCE, 1952, Vol. 117, pp. 545-578.
[18] Johnston, B.G., “Guide to Stability Design Criteria for Metal Structures”, Third Edition, John Wiley & Sons, 1976.
[19] BS 5950, “Structural use of Steel Work in Building: Part 1, Code of Practice for Design in Simple and Continuous Construction, Hot Rolled Sections”, British Standard Institution, London, 1985.
[20] Horne, M.R., “Plastic Theory of Structure”, Thomas Melson and Sons, Ltd, 1971.