Advanced Steel Construction

Vol. 18, No. 1, pp. 495-505 (2022)


 NUMERICAL STUDY OF TWO NOVEL CONNECTIONS WITH

SHORT END I OR H STUB IN STEEL STRUCTURES

 

Mehrdad Taheripour 1, Farzad Hatami 1, 2 , * and Reza Raoufi 1

1 Department of Civil Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran

2 Department of Structures and Earthquake Research Center, Amirkabir University of Technology, Tehran, Iran

*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)

Received: 17 December 2020; Revised: 16 June 2021; Accepted: 4 July 2021

 

DOI:10.18057/IJASC.2022.18.1.8

 

View Article   Export Citation: Plain Text | RIS | Endnote

ABSTRACT

In this study, two novel steel connections are introduced by replacements in the conventional end-plate connection with an H-or I-shaped cross-section as a Short Stub Column (SSC). In the first connection, the SSC flange is bolted to the column flange, and the beam is welded to the stub flange. In the second connection, after welding the SSC flange to the column flange and welding the beam to an end-plate, the end-plate is bolted to the SSC flange. The flange and web of the stub are reinforced using horizontal stiffeners to transfer the beam moment. Stiffeners could be employed with various thicknesses and configurations such that the strength and ductility of the joint could be adjusted. In this study, the Finite Element Model (FEM) model of a conventional welded and bolted end-plate connection, subjected to cyclic loading, is primarily calibrated using experimental data from previous studies. After confirming the model's performance, the behavior of the two proposed connections, in comparison with it, has been studied. The hysteresis diagrams have been obtained for each case, followed by extracting the effective parameters and comparing them. The results show that the two Proposed Connections reduce the stress in the panel zone and increase the ductility compared to the previously confirmed end-plates. All the samples in this study satisfy the fundamental requirements for rigid beam-to-column connections, according to AISC.

 

KEYWORDS

Bolted end-plate connection, Stub steel connections, Panel zone, Hysteresis diagrams, PEEQ


REFERENCES

[1] Moghadam A, E Estekanchi H, Yekrangnia M. Evaluation of PR steel frame connection with torsional plate and its optimal placement. Scientia Iranica. 2018 Jun 1;25(3):1025-38.

[2] SAC J. State of the art report on connection performance Report No FEMA-355D. Federal Emergency Management Agency (FEMA), Washington. 2000.

[3] Alhendi H, Celikag M. Finite element prediction of reverse channel connections to tubular columns behavior. Engineering Structures. 2015 Oct 1;100:599-609.

[4] Mirghaderi SR, Torabian S, Keshavarzi F. I-beam to box–column connection by a vertical plate passing through the column. Engineering Structures. 2010 Aug 1;32(8):2034-48.

[5] Miller DK. Lessons learned from the Northridge earthquake. Engineering structures. 1998 Apr 1;20(4-6):249-60.

[6] Tremblay R, Filiatrault A, Timler P, Bruneau M. Performance of steel structures during the 1994 Northridge earthquake. Canadian Journal of Civil Engineering. 1995 Apr 1;22(2):338-60.

[7] Tremblay R, Filiatrault A, Bruneau M, Nakashima M, Prion HG, DeVall R. Seismic design of steel buildings: lessons from the 1995 Hyogo-ken Nanbu earthquake. Canadian Journal of Civil Engineering. 1996 Jun 1;23(3):727-56.

[8] American Institute of Steel Construction (AISC), Seismic Provisions for Structural Steel Buildings, AISC ANSI/AISC 341-16, Chicago, IL, 2016.

[9] Garoosi AM, TahamouliRoudsari M, Hashemi BH. Experimental evaluation of rigid connection with reduced section and replaceable fuse. InStructures 2018 Nov 1 (Vol. 16, pp. 390-404). Elsevier.

[10] Behrooz SM, Erfani S. Parametric study of Stub-Beam Bolted Extended End-Plate connection to box-columns. Journal of Constructional Steel Research. 2020 Aug 1;171:106155.

[11] Shen Y, Christopoulos C, Mansour N, Tremblay R. Seismic design and performance of steel moment-resisting frames with nonlinear replaceable links. Journal of Structural Engineering. 2011 Oct 1;137(10):1107-17.

[12] Li X. Moment-rotation behaviour of universal beam to tubular column connections using reverse channel. The University of Manchester (United Kingdom); 2012.

[13] O.Yılmaz, S Bekiroğlu. Performance Evaluation of Weak-Axis Steel Moment Connections. XVI INTERNATIONAL SCIENTIFIC CONFERENCE VSU'2016.

[14] Hu G, Huang W, Xie H. Mechanical behavior of a replaceable energy dissipation device for precast concrete beam-column connections. Journal of Constructional Steel Research. 2020 Jan 1;164:105816.

[15] Peng H, Ou J, Mahin S. Design and numerical analysis of a damage-controllable mechanical hinge beam-to-column connection. Soil Dynamics and Earthquake Engineering. 2020 Jun 1;133:106149.

[16] Shi Q, Yan S, Kong L, Bu X, Wang X, Sun H. Seismic behavior of semi-rigid steel joints—Major axis T-stub and minor axis end-plate. Journal of Constructional Steel Research. 2019 Aug 1;159:476-92.

[17] Jiang J, Chen S. Experimental and numerical study of double-through plate connections to CFST column. Journal of Constructional Steel Research. 2019 Feb 1;153:385-94.

[18] Zhang Y, Li Q, Zhuge Y, Liu A, Zhao W. Experimental study on spatial prefabricated self-centering steel frame with beam-column connections containing bolted web friction devices. Engineering Structures. 2019 Sep 15;195:1-21.

[19] Liu Y, Huang SS, Burgess I. Component-based modelling of a novel ductile steel connection. Engineering Structures. 2020 Apr 1;208:110320.

[20] Sumner EA. Unified design of extended end-plate moment connections subject to cyclic loading (Doctoral dissertation, Virginia Tech).

[21] British Standards Institution. Mechanical Properties of Fasteners Made of Carbon Steel and Alloy Steel: Set Screws and Similar Threaded Fasteners Not Under Tensile Stresses. British Standards Institution; 1999.

[22] ASCE/SEI Seismic Rehabilitation Standards Committee. Seismic rehabilitation of existing buildings. ASCE/SEI. 2007:41-06.

[23] Venture SJ. SAC. Protocol for Fabrication, Inspection, Testing and Documentation of Beam-Column Connection Test and Other Experimental Specimens. SAC Rep. SAC/BD-97/02, Sacramento, California; 1997.

[24] FEMA A. 440, Improvement of nonlinear static seismic analysis procedures. FEMA-440, Redwood City. 2005;7(9):11.

[25] AISC A. AISC 341-10. Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction. Inc., Chicago, IL. 2010.