Advanced Steel Construction

Vol. 19, No. 2, pp. 130-142 (2023)


 MOMENT-ROTATION MODEL OF EXTERNAL COVER PLATE JOINTS

BETWEEN STEEL BEAMS AND CONCRETE-FILLED SQUARE STEEL TUBULAR

COLUMNS WITH INNER I-SHAPED CFRP PROFILE

 

Guo-Chang Li 1, Ming-Hao Shen 1, *, Da-Cang Ji 1, Han-Bin Ge 2 and Xu Liu 1

1 School of Civil Engineering, Shenyang Jianzhu University, Shenyang, Liaoning 110168, China

2 Department of Civil Engineering, Meijo University, Nagoya, Aichi 468-8502, Japan

* (Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)

Received: 13 May 2022; Revised: 11 July 2022; Accepted: 20 July 2022

 

DOI:10.18057/IJASC.2023.19.2.5

 

View Article   Export Citation: Plain Text | RIS | Endnote

ABSTRACT

As a new type of beam-column joint, external cover plate joints can be used in concrete-filled square steel tubular (CFSST) structures. To accurately analyze the mechanical characteristics of this novel joint during structural design, it is necessary to investigate the moment-rotation relationships. Based on the analysis of the force-transferring mechanism, the formulas to decide the initial rotation stiffness and ultimate bending moment are founded by using the component analysis method, while the finite element analysis results are also utilized to verify these formulas. Considering the advantages and disadvantages of the existing typical moment-rotation models, a new representation for calculating the moment-rotation curve of the external cover plate joints is proposed using the ultimate bending moment and initial rotation stiffness as two basic parameters. The research reveals that the moment-rotation model proposed in this paper is able to take all loading stages of this joint into account, which facilitates the analysis of yield and ultimate loads. In addition, this model is smooth and continuous at the piecewise points to avoid numerical problems that may be caused in the calculation. Comparing the moment-rotation curves obtained by the calculation model and finite element simulation, the results show good consistency, demonstrating that the moment-rotation model presented in this paper is applicable to the analysis and design of the external cover plate joints.

 

KEYWORDS

Concrete-filled square steel tubular, External cover plate joint, I-shaped CFRP profile, Initial rotational stiffness, Ultimate bending moment, Component method, Moment-rotation model


REFERENCES

[1] Zhong S.T., The concrete-filled steel tubular structures, Beijing: Tsinghua University Press, 2003.

[2] Li G.C., Yu Y., Yang Z.J., Fang C., Ge H.B. and Liu Y.P., “Mechanical behavior of high-strength concrete filled high-strength steel tubular stub columns stiffened with encased I-shaped CFRP profile under axial compression”, Composite Structures, 275: 114504, 2021.

[3] Li G.C., Zhou B. and Pan J.H., “Finite element analysis on concrete-filled square steel tube short columns with inner CFRP profiles under axial compression”, Applied Mechanics and Materials, pp. 335-339, 2014.

[4] Feng X., Li G.C., Yang Z.J. and Cao W.Z., “Performance study on the mechanical behavior of a concrete-filled square steel tubular middle-long columns with inner I-shaped CFRP profiles under bi-axial eccentric loading”, Progress Steel Building Structures, 23(8):32-42+52, 2021. (in Chinese)

[5] Li W.Q., Chen Y.Y., Wang W., Xu Y.J. and Lv X.D., “Experimental study of external diaphragm joint connecting CHS column and H-shaped beam”, Advanced Steel Construction, 6(1): 578-588, 2010.

[6] Goswami R., Murty C.V.R., “Externally reinforced welded I-beam-to-box-column seismic connection”, Journal of Engineering Mechanics, 136(1), 23-30, 2010.

[7] Ye Q., Wang Y., Wang Z., Lin Y., Shu C. and Zhang F., “Experimental study of through diaphragm bolted joint between H-beam to CFST column”, Journal of Constructional Steel Research, 182, 106647, 2021.

[8] Xu P.Z., Chen C., Yang L. and Zhu Y.G., “Finite element analysis on the seismic behavior of circular steel tubular column to H-shaped steel beam joint with cover-plate externally strengthened ring”, Progress in Steel Building Structures, 23(2): 14-21, 2021. (in Chinese)

[9] Cao S., Shu G., Lin K. and Qin Y., “Experimental seismic behaviour of bottom-through-diaphragm and top-ring connection to SST columns”, Journal of Constructional Steel Research, 150, 249-260, 2018.

[10] Wang W.D., Han L.H. and Uy B., “Experimental behaviour of steel reduced beam section to concrete-filled circular hollow section column connections”, Journal of Constructional Steel Research, 64(5), 493-504, 2008.

[11] Chen W.F., Torma S., Advanced Analysis in Steel Frames, Boca Raton: CRC Press, 1993.

[12] Masarira A., “The effect of joints on the stability behaviour of steel frame beams”, Journal of Constructional Steel Research, 58(10), 1375-1390, 2002.

[13] Faella C., Piluso V. and Rizzano G., Structural steel semirigid connections: Theory, Design and Software, Boca Raton, Florida: CRC Press LLC, 1999.

[14] Ding J.M., Shen Z.Y., “Influence of semi-rigid joint on internal force and displacement of steel frame structure”, Building Structure, 6, 8-12, 1991. (in Chinese)

[15] Wu F.H., Chen W.F., “A design model for semi-rigid connection”, Engineering Structures, 12(2), 88-97, 1990.

[16] Yee Y.L., Melchers R.E., “Moment-rotation curves for bolted connections”, Journal of Structural Engineering, 112(3), 615-635, 1986.

[17] Frye M., Morris G.A., “Analysis of flexibly connected steel frames”, Canadian Journal of Civi1 Engineering, 2(3), 280-291, 1975.

[18] Colson A., “Theoretical modeling of semirigid connections behavior”, Journal of Constructional Steel Research, 19(3), 213-224, 1991.

[19] Kishi N., Chen W.F., “Moment-rotation relation of semirigid connection with angles”, Journal of Structural Engineering, 116, 1813-1834, 1990.

[20] Ang K.M., Morris G.A., “Analysis of three-dimensional frames with flexible beam-column connections”, Canadian Journal of Civil Engineering, 11(2), 245-254, 1984.

[21] GB50017-2017, Steel Structure Design Standard. Beijing: China Construction Industry Press, 2017.

[22] GB50011-2010, Code for Seismic Design of Buildings. Beijing: China Construction Industry Press, 2016.

[23] JGJ99-2015, Technical Specification for High Rise Civil Steel Structures. Beijing: China Construction Industry Press, 2015.

[24] Han L.H., Concrete Filled Steel Tubular Structures¬¬: Theory and Practice. Beijing: Science Press, 2007.

[25] Li G.C., Zhan Z.C., Yang Z.J., Fang C. and Yang Y., “Behavior of concrete-filled square steel tubular stub columns stiffened with encased I-section CFRP profile under biaxial bending”, Journal of Constructional Steel Research, 169, 106065, 2020.

[26] Li G.C., Zhu Z.H., Sun X., Liu X.H. and Han Y.W., “Experimental research on concrete-filled square steel tubular slender columns with inner I-shaped CFRP under axial compression”, Journal of Building Structures, 38(S1), 226-232, 2017. (in Chinese)

[27] Zuo B., “Pseudo-static experimental study of H-shaped beams to cold-formed square steel tube columns connections with different outer diaphragm”, Qingdao Technological University, 2014. (in Chinese)

[28] Yuan Z.R., “The Research on the mechanical performance of the square concrete filled steel tube with T-stub connector”, Hunan University, 2013. (in Chinese)

[29] Liu H.C., Hao J.P., Xue Q. and Huang Y.Q., “Stress response and initial stiffness of side plate connections to WCFT columns”, Advanced Steel Construction, 17(3), 306-317, 2021.

[30] Zhao Q.W., Zhang S.M. and Jiang S.F., “Calculation model of initial rotational stiffness of steel beam-to-column bolted end-plate connections”, Engineering Mechanics, 26(6), 226-232, 2009. (in Chinese)

[31] Matsui C., “Strength and behavior of frames with concrete filled square steel tubular columns under earthquake loading”, Proceedings of the international specialty conference on concrete filled tubular structures, 104-111, 1985.

[32] EN1993-1-8, Eurocode 3: Design of Steel Structures - Part 1-8: Design of joints, 2010.

[33] Zhao J.H., Fan J.C. and Gao W.Q., “Moment-rotation analyses model of flush end-plate bolted connections between H-shape steel beams and rectangular CFST columns”, Engineering Mechanics, 38(6), 249-260, 2021. (in Chinese)