Vol. 21, No. 3, pp. 194-203 (2025)
STUDY ON SHEAR BEHAVIOR OF T-SHAPED SHEAR CONNECTORS
IN PREFABRICATED CONCRETE COMPOSITE FLOOR SLAB
Zeng-Mei Qiu *, Wen-Zhuang Pei, Guo-Chang Li and Zhi-Jian Yang
School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China
*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 28 November 2024; Revised: 27 December 2024; Accepted: 1 January 2025
DOI:10.18057/IJASC.2025.21.3.2
View Article |
Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
This study proposed to apply T-shaped shear connectors to join prefabricated concrete slabs with H-beams and thereby ensure the overall working performance of building floor systems. The push-out tests on T-shaped connector specimens with different flange and web thicknesses were conducted aiming to investigate the shear behavior of this connector. Then the finite element software ABAQUS was used to establish test models, and the accuracy of the established models were verified according to the comparative experimental results to analyze the stress development process and key parameters influencing connector shear behavior. The results showed that the T-shaped connector with high initial stiffness and shear capacity, and its characteristic displacement complied with the lower limit value of permissible slip specified for the flexible shear connector in Eurocode 4, confirming its excellent ductility. The connector web thickness had the greatest effect on shear capacity, the second was the steel yield strength, whereas the connector width had the least influence. Finally, the recommended cross-sectional dimensions for the T-shaped connector were given, as well as the shear bearing capacity equation for this connector was derived, which could provide theoretical basis and design suggestions for its application in prefabricated concrete composite floor structure.
KEYWORDS
Prefabricated concrete composite floor slabs, Push-out test, T-shaped shear connector, Shear behavior, Finite element simulation
REFERENCES
[1] Yu S, Liu Y and Wang D. “Review of thermal and environmental performance of prefabricated buildings: Implications to emission reductions in China”. Renewable and Sustainable Energy Reviews, 137:110472, 2021.
[2] Li X, Xie W and Yang T. “Carbon emission evaluation of prefabricated concrete composite plates during the building materialization stage”. Building and Environment, 232, 110045, 2023.
[3] LI G, CAO K and YANG Z. “Finite Element Analysis of Steel Reinforced Concrete Stub Columns with New Shear Connectors under Axial Compression”. Journal of Shenyang Jianzhu University (Natural Science), 38(2):202-210, 2022. (in Chinese)
[4] Yossef M, Chen A and Elsayad M. “Deconstructable variable stiffness shear connectors in FRP deck resting on multigirder bridge system: Analytical model”. Engineering Structures, 307:117932, 2024.
[5] Jakovljević I, Spremić M and Marković Z. “Shear behaviour of demountable connections with bolts and headed studs”. Advanced Steel Construction (Accepted for Publication on 16th May 2023), 2023.
[6] Xu Q, Sebastian W and Lu K. “Development and Performance of Innovative Steel Wedge Block–Crossed Inclined Stud–UHPC Connections for Composite Bridge”. Journal of Structural Engineering, 148(9):04022128, 2022.
[7] Shariati A T A. “Monotonic behavior of C and L shaped angle shear connectors within steel-concrete composite beams: an experimental investigation”. Steel & Composite Structures: An International Journal, 35(2):237-247, 2020.
[8] Viest I M. “Full-scale tests of channel shear connectors and composite t-beams”. University of Illinois at Urbana-Champaign, 1951.
[9] Shariati M, Sulong N H R and Suhatril M. “Comparison of behaviour between channel and angle shear connectors under monotonic and fully reversed cyclic loading”. Construction and Building Materials, 38(38):582-593, 2013.
[10] Haroon M, Lee H D and Shin K J. Performance of angle shear connectors for U-shaped steel concrete infilled composite beams. Heliyon, 10(3): e25119, 2024.
[11] Arévalo D, Hernández L and Gómez C. “Structural performance of steel angle shear connectors with different orientation”. Case Studies in Construction Materials, 14: e00523, 2021.
[12] Hajime O, Yoshio K. “JSCE Research Subcommittee on Steel-Concrete Sandwich Structures”. Design code for steel-concrete sandwich structures–Draft, 20:1-21, 1992.
[13] ZHOU W, BAI J and LEI Y. “Experimental study on the lattice type of angle steel connectors──the fourth of the series of studies on steel-concrete composite truss”. Journal of Hefei University of Technology (Natural Science Edition), (02):126-130, 1994. (in Chinese)
[14] CUI J, ZHANG X. “The Study of Composite Beam Flexural Test and Shear Strength of Angle Connectors. Journal of Anhui Jianzhu University, 31(01):1-9, 2023. (in Chinese)
[15] TANG L, FAN J and NIE J. “Experimental study on the mechanical performance of angle shear connectors with and without concrete gaps”. Engineering Mechanics, 37(10): 45-55+115, 2020. (in Chinese)
[16] Soty R, Shima H. “Formulation for shear force–relative displacement relationship of L-shape shear connector in steel–concrete composite structures”. Engineering Structures, 46:581-592, 2013.
[17] WANG X, DENG W and ZHANG J. “Mechanical characteristics of shear connectors under repeated loads”. Journal of Jiangsu University of Technology (Natural Science Edition), 39(06):708-713, 2018. (in Chinese)
[18] EN1994-1-1, “Eurocode 4: Design of composite steel and concrete structures. Part 1-1: General rules and rules for buildings”. Brussels: CEN; 2004.
[19] QIU Z. “Development and Performance Study of New Connection between Prefabricated Concrete Laminated Floor Slab and Steel Beam”. Shenyang: Shenyang Jianzhu University, 2014. (in Chinese)
[20] YAN Y, DENG P and HOU H. “Experimental study on shear resistance of bolt connector in steel-concrete composite beam”. Journal of Shandong University of Science and Technology (Natural Science), 40(02): 51-59, 2021. (in Chinese)
[21] YANG Y, ZHANG S and CHEN X. “Experimental study on the shear behavior of a bolt connector in a steel-concrete composite beam”. Journal of Harbin Engineering University. 45(06):1076-1084, 2024. (in Chinese)
[22] GB 50010—2010, “Code for design of concrete structures”. China Architecture & Building Press, Beijing, 2010. (in Chinese)
[23] LI G, WANG Z and YANG Z. “Experimental study on shear behavior of π-type crestbond shear connectors”. Journal of Building Structures, 43(06):75-86, 2022. (in Chinese)
[24] Luo Y B, Sun S K and Yan J B. “Shear behavior of novel demountable bolted shear connector for prefabricated composite beam”. Advanced Steel Construction, 18(4):745-752, 2022.
[25] REN C, YUAN Y, CHEN Y. “Finite Element Analysis on Shear Performance Large-Diameter Short Stud Connectors in Prefabricated Steel-Thin UHPC Composite Beams”. Industrial Construction, 53(11):180-187, 2023. (in Chinese)
[26] Yan J B, Zhang W. “Numerical analysis on steel-concrete-steel sandwich plates by damage plasticity model: From materials to structures”. Construction and Building Materials, 149: 801-815, 2017.
[27] GB/T 706-2016, “Hot rolled section steel. Standards Press of China”, Beijing, 2016. (in Chinese)
[28] NIE J, SUN G. “Study on steel channel shear connector of steel-concrete composite beams”. Industrial Construction, (10):8-13+57, 1990. (in Chinese)
[29] GB 50917-2013, “Code for design of steel and concrete composite bridges”. China Planning Press, Beijing, 2013. (in Chinese)
[30] ANSI/AISC 360-10, “AISC. Specification for structural steel buildings”, American Institute of Steel Construction, Chicago, Illinois, 2010.