Vol. 22, No. 5, pp. 483-498 (2026)
SEISMIC PERFORMANCE AND DAMAGE EVALUATION OF
IRREGULAR STEEL JOINTS IN MODERN CHINESE TRADITIONAL-STYLE
BUILDINGS WITH BLIND BOLTS
Zhan-Jing Wu 1, 2, Jin-Shuang Dong 3, *, Yan Sui 4 and Jia-Ning Wang 2
1 International Union Laboratory of New Civil Engineering Structure of Henan Province, Luoyang 471023, China
2 School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology,
Luoyang 471023, China
3 College of Civil Engineering and Architechture, Hainan Univerisitey, Haikou 570228, China
4 College of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 4 November 2025; Revised: 20 March 2026; Accepted: 31 March 2026
DOI:10.18057/IJASC.2026.22.5.1
View Article |
Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
Steel modern Chinese traditional-style buildings (MCTBs) commonly adopt fully welded connections. However, the use of circular hollow section (CHS) columns at beam-column joints, coupled with strict architectural aesthetic requirements, presents significant challenges for the application of conventional bolted connections. This issue represents a critical technical bottleneck that hinders the development of prefabricated construction in such buildings. To address this challenge, a novel prefabricated joint configuration based on blind bolt-T-stub assemblies was proposed. Four 1:2.6-scale specimens, including two single-beam column joints and two double-beam column joints, were fabricated and tested under low-cycle reversed loading to evaluate their seismic performance in terms of failure modes, hysteretic behavior, ductility, energy dissipation, and stiffness degradation. Furthermore, refined finite element (FEA) models were established to reproduce the experimental deformation patterns, stress distribution, and moment–rotation hysteresis behavior, including the relative slippage of the double-beam connectors. All specimens conformed to the strong-column weak-beam design principle, with damage primarily concentrated in the T-stub region. Compared to the single-beam column joints, the double-beam column joints demonstrated superior load-bearing capacity, enhanced energy dissipation, and greater safety redundancy. Moreover, increasing the T-stub thickness further improved the overall performance. Seismic damage was quantified using a modified Park-Ang damage model, confirming that the proposed prefabricated joint exhibits favorable seismic behavior and practical engineering applicability. The findings offer an effective structural solution for the industrialized seismic design of beam-column joints in steel MCTBs.
KEYWORDS
Steel modern Chinese traditional-style buildings, Irregular steel joints, Blind bolts, Low-cycle reversed loading, Seismic performance, Damage evaluation
REFERENCES
[1] Sha B, Xie L, Yong X, Li A. An experimental study of the combined hysteretic behavior of dougong and upper frame in Yingxian Wood Pagoda. Constr Build Mater 2021; 305: 124723.
[2] Zhang X, Liu L, Cui L, et al. Nonlinear dynamic analysis of ancient timber structures with rotary friction dampers. J Build Eng 2025, 100: 111707.
[3] Xue J, Qi L, Li Y, Che S, Wang G, Wei S. Quasi-static test on steel frame structure in traditional style buildings. J Build Struct 2017;38(8):133–40.
[4] Xue J, Ma L, Ge Z, Wu K, Liu Z. Experimental study on seismic performances of composite column with SRC square section and RC circular section in traditional style buildings. J Civ Eng 2018;51(2):21–31.
[5] Xue J, Ma L, Lin J, Wu K, Ge H. Experimental study on seismic behavior of imitated ancient building connections between concrete filled square steel tubular columns and reinforced concrete circular columns. J Build Struct 2018;39(4):37-44.
[6] Qi L, Xue J. Pseudo dynamic test and time-history analyses of traditional-style steel frame structures. International Journal of Steel Structures 2018;18(2):402-16.
[7] Xue J, Zhai L, Li H, Zhao X, Wu K. Seismic performances of RC-CFST composite frame in traditional style building under low cycle reversed loading. J Build Struct 2019;40(9):53-62.
[8] Qi L, Cao Y, Xue J, et al. Seismic performance evaluation and engineering application of modern Chinese traditional-style buildings: The state-of-art review. Structures, 2023, 56: 105022.
[9] Xue J, Wu Z, Sui Y, Ge H, Wu K. Experimental study and numerical analysis on aseismic performance of steel double-beams-column interior-joints in traditional style building. Eng Mech 2016;33(5):97-105.
[10] Qi L, Xue J, Leon RT. Experimental and analytical investigation of transition steel connections in traditional-style buildings. Eng Struct 2017;150:438-450.
[11] Xue J, Ma L, Wu Z, et al. Influence analysis of bracket set on seismic performance of steel eave columns in Chinese traditional style buildings[J]. Struct Des Tall Spec Build 2018, 27(8): e1462.
[12] Xue J, Ma L, Wu Z. Seismic Performance of Steel Joints Between Double Beams and Column in Chinese Traditional Style Buildings. Int J Steel Struct 2018;18(2):417-432.
[13] Xue J, Wu Z, Sui Y, Liu Z. Experimental study on seismic performance of steel double-beams column exterior joints in antique style building. J Build Struct 2015; 36(3):80-89.
[14] Xue J, Qi L, Yang K, Wu Z. Dynamic experimental study on single and double beam-column joints in steel traditional-style buildings. Struct Eng Mech 2017;63 (5):617-628.
[15] Qi L, Xue J, Sui Y, Wu Z. Smart retrofitting of irregular steel joints in traditional Chinese buildings by viscous dampers. Eng Struct 2021;228:111526.
[16] Yuan Z, Qi L, Xue J. Seismic performance of steel semi-rigid friction-damped joints with replaceable angles in modern Chinese traditional-style buildings. J Constr Steel Res 2023;207:107948.
[17] Yuan Z, Qi L, Xue G, et al. Resilient joints with SMA bar-shear friction damper (SSFD) device in steel modern Chinese traditional-style buildings: Seismic performance evaluation and optimized design. J Build Eng 2024, 82: 108300.
[18] Qi L, Yuan Z, Xue J. Experimental and numerical study on seismic performance of steel semi-rigid joints equipped with SMA bars and friction dampers. Eng Struct 2024, 301: 117320.
[19] Liu Y, Sun L, Zhang Y, et al. Proposed analytical models for bolted T-stubs to square hollow section column connection using thread-fixed one-side bolts under tension. J Build Eng 2022, 52: 104398.
[20] Tizani W, Wang Z, Hajirasouliha I. Hysteretic performance of a new blind bolted connectionto concrete filled columns under cyclic loading: an experimental investigation. Eng Struct 2013, 46(1): 535-546.
[21] Mahmood M, Tizani W, Sansour C. Effect of tube thickness on the face bending for blind-bolted connection to concrete filled tubular structures. Int J Civ Archit Struct Constr Eng 2014, 8(9): 897-903.
[22] Pitrakkos T, Tizani W. Experimental behaviour of a novel anchored blind-bolt in tension. Eng Struct 2013, 49: 905-919.
[23] Tizani W, Mahmood M, Dionysios B. Effect of concrete infill and slenderness on column-face component in anchored blind-bolt connections. J Struct Eng 2020, 146(04): 1-39.
[24] Cabrera M, Tizani W, Mahmood M, et al. Analysis of Extended Hollo-Bolt connections: Combined failure in tension. J Constr Steel Res 2020, 165: 105776.
[25] Cabrera M, Tizani W, Ninic J, et al. Experimental and numerical analysis of preload in Extended Hollo-Bolt blind bolts. J Constr Steel Res 2021, 186: 106885.
[26] Zhang Y, Liu M, Ma Q, et al. Yield line patterns of T-stubs connected by thread-fixed one-side bolts under tension. J Constr Steel Res 2020, 166: 105932.
[27] Liu M, Zhu X, Wang P, et al. Tension strength and design method for thread-fixed one-side bolted T-stub[J]. Eng Struct 2017, 150: 918-933.
[28] Dhanapal J, Das S, Ghaednia H, et al. Experimental study on structural performance of flow drilled connections in HSS members. J Constr Steel Res 2020, 164: 105786.
[29] Lee J, Goldsworthy HM, Gad EF. Blind bolted T-stub connections to unfilled hollow section columns in low rise structures. J Constr Steel Res 2010;66 (8):981-992.
[30] Lee J, Goldsworthy HM, Gad EF. Blind bolted moment connection to unfilled hollow section columns using extended T-stub with back face support. Eng Struct 2011;33(5):1710-1722.
[31] Wang W, Li M, Chen Y, et al. Cyclic behavior of endplate connections to tubular columns with novel slip-critical blind bolts. Eng Struct 2017, 148: 949-962.
[32] Gao X, Wang W, Teh L H, et al. A novel slip-critical blind bolt: Experimental studies on shear, tensile and combined tensile-shear resistances. Thin-Walled Struct 2022, 170: 108630.
[33] JGJ82-2011, Technical specification for high strength bolt connections of steel structures, 2011.
[34] Gao X, Wang W, Teh L H. Experimental and numerical investigations of tensile behavior of slip-critical blind bolts anchored in concrete-filled steel tubes. Structures 2023, 55: 354-369.
[35] Jiao W, Wang W, Chen Y, et al. Seismic performance of concrete-filled SHS column-to-beam connections with slip-critical blind bolts. J Constr Steel Res 2020, 170: 106075.
[36] GB 50017-2017, National Standard of People’s Republic of China. Code for Design of Steel Structures, China Plan Press, Beijing, 2017. (In Chinese)
[37] Liang, S. A Pictorial History of Chinese Architecture; MTT Press: Boston, MA, USA, 1984.
[38] GB50011-2010; Code for Seismic Design of Buildings. China Architecture & Building Press: Beijing, China, 2010. (In Chinese)
[39] GB50661-2011; Code for Welding of Steel Structures. Standards Press of China: Beijing, China, 2011. (In Chinese)
[40] GB/T228.1-2021; Metallic Materials-Tensile Testing at Ambient Temperature. Chinese Standard Press: Beijing, China, 2021. (In Chinese)
[41] JGJ101-2015; Specification of Testing Methods for Earthquake Resistant Building. China Building Industry Press: Beijing, China, 2015. (In Chinese)
[42] Qi L, Xue J, Xu D. Experimental study and theoretical model of seismic behavior of steel transition columns considering damage effect. J Build Struct 2021;42(S1): 239-248
[43] Usami T, Kumar S. Inelastic seismic design verification method for steel bridge piers using a damage index based hysteretic model. Eng Struct 1998;20(4-6): 472-480.
[44] Liu H, Yan S, Wang X, et al. Experimental study on the seismic damage behavior of composite joints of concrete-filled steel tube column with blind bolts. Structures 2024;70: 107767.
[45] Xiao S, Bu X, Chen Y, et al. Investigating the damage-based seismic performance of the blind bolt-connected steel framework. Structures 2024, 69: 107388.
[46] EN 1993-1-8; Eurocode 3: Design of Steel Structures-Part 1-8: Design of Joints. European Committee for Standardization (CEN): Brussels, Belgium, 2005.